HSM maintenance
The nShield Connect contains only two user-replaceable parts:
-
The PSUs.
-
The fan tray module.
Replacing a PSU or fan tray module does not affect FIPS 140 validations for the HSM, or result in a tamper event. However, in the very rare event that a PSU or fan tray module requires replacement, contact Support before carrying out the replacement procedure.
| Do not allow a fan tray to be removed from the nShield Connect for longer than 30 minutes, otherwise a tamper event will occur. |
For more information about replacing either a PSU or the fan tray module, see the Installation Sheet that accompanies the replacement part.
| Breaking the security seal or dismantling the nShield Connect voids your warranty cover, and any existing maintenance and support agreements. |
Flash testing the module
The module is designed to comply with IEC/EN 60950-1 but should be tested only by trained safety professionals. Because the module is fitted with radio frequency interference suppressors, it is recommended that only a DC test be performed.
| Repeated application of the flash test can damage safety insulation. |